![]() It also carries a tamper-evident warning label.Įxclusive welding process eliminates interior rough spots and sharp edges that can damage the diaphragm and liner.ĭeep-drawn steel domes offer twice the strength of rolled steel while minimizing weight of the Well Water Tank. Welded air valve is permanently attached rather than mechanically threaded to prevent loss of air pressure and to minimize stress on the well's pump system. Polypropylene liner provides a 100% corrosion resistant, non-metallic rigid water reservoir that is listed by NSF International Standard 61. Heavy duty butyl diaphragm is extremely resistant to bacterial growth and meets FDA requirements for potable water supply. Butyl is the best-known elastomer to prevent air loss. It conforms exactly to the shell configuration without stretching, creasing, or forming bubbles or corners that could trap water or sediment. Heavy duty butyl diaphragm of the Amtrol WX-202-UG well pressure tank is the thickest in the industry and features seamless construction for uniform strength and flexibility. Precharge Pressure for the WX-202-UG Well Water System Pressure Tank is 38 PSIG and the Maximum Working Pressure is 125 PSIG. Turn on the circuit breaker and retest the sensor's cut-on level.Amtrol WX-202-UG (144S56) Well-X-Trol is an Well Water System Pressure Tank (Underground Model) with 20 gallons volume and 1" female threaded coupling system connection. WELL-X-TROL Well Tank SKU: WX-251 Amtrol (35) 956. If the well pump turns on after the Well-X-Trol stops forcing water out of the faucet, turn off the well pump's circuit breaker and increase the sensor's cut-on switch. WELL-X-TROL Well Tank SKU: WX-202 Amtrol (77) 295.00 each ADD TO CART Add to List 234 Mon, May 15 Compare WX-251 (145S10), 62 Gal. Open a faucet and observe the well pump and the faucet. Drain the Well-X-Trol, turn on the well pump's circuit breaker and retest the sensor's cut-out level. ![]() If the well pump turns off before reaching the maximum water pressure, turn off the circuit breaker and increase the pressure sensor's cut-out switch. If the pressure gauge exceeds the Well-X-Trol's stated maximum water pressure, turn off the well pump's circuit breaker and lower the pressure sensor's cut-out switch. Observe the well pump's pressure gauge as the Well-X-Trol fills. ![]() ![]() The proper size hex-head screwdriver turns the adjustment bolts. The sensor's cut-out and cut-on switches usually use 1/4-, 5/15- or 3/8-inch hex-head adjustment bolts. The pressure sensor mounts to either the well pump or the water line between the well pump and the Well-X-Trol. Heavy duty butyl diaphragm of the Amtrol WX-202 well pressure tank is. Precharge Pressure for the WX-202 Well Water System Pressure Tank is 38 PSIG and the Maximum Working Pressure is 125 PSIG. Remove the well pump's pressure sensor cover, using the correct screwdriver. Amtrol WX-202 (144S29) Well-X-Trol is an Well Water System Pressure Tank (Stand Model) with 20 gallons volume and 1' female threaded system connection. Set the Well-X-Trol's air valve cap on the air valve. If the Well-X-Trol tank's air pressure drops below 10 percent of the factory setting, add air to the tank with an air pump until the pressure reaches the factory setting. If the tank's air pressure exceeds the factory setting's limit, depress the air valve's needle valve for 10 seconds and retest. Amtrol WELL-X-TROL Professional WX202UG WX Series Underground Well Tank With Pump Stand, MNPT Discharge, 20 gal, 1 in Discharge, 15 in Dia Overall. The gauge's reading must remain within 10 percent of the factory setting. Compare the air-pressure gauge's reading with the Well-X-Trol's stated air-pressure factory setting. This lists the factory's air-pressure setting and the tank's maximum water pressure.Ĭheck the air pressure in the Well-X-Trol tank with an air-pressure gauge. Inspect the Well-X-Trol's identification label.
0 Comments
Leave a Reply. |